Before using this product:
(1) Check whether the glass disc and vibrator are stopped.
(2) Check for any debris on the glass disc and groove of vibrating feeder.
(3) Select the appropriate Orbit, see the accompanying drawings.
(4) Adjustment method of orbit:
1. The inner and outer orbit should be parallel to each other, a width slightly larger than the diameter of the capsules or tablets, its material outlet shall be placed at an intermediate position of electric eye base.
2. Outer orbit should be affixed to the front of the circumference to ensure a smooth sliding of the capsule.
3. Adjust Skew, its height should be slightly larger than the thickness of tablets.
(5) With the size of the bottle and medicine, appropriate chose the material outlet.
(6) Adjust the height of lifting plate and lock Y-Locator.
(7) Turn on the power, set the number, slow start the glass disc and vibrator, check whether tablets slide smoothly and digital display is correct, if both are normal, set number to zero and start the operation.
model | YL-2 |
Speed | 1000-1800pcs/min (1,∅7mm、12mm tablet,2400pcs/min. 2,1#capsule 0.4g/pcs, 1400pcs/min.) |
Loading range | 2~9999 grains/tablet (adjustable) |
Hopper capacity | 10L(1# capsule can hold 10600 capsules) |
Bottle height adjustment range | ≤240MM |
Voltage/Power | 110-220V 50HZ-60HZ/0.1KW |
Net weight/gross weight | 65KG/92KG |
Equipment size | 81x72x84CM |
Package dimensions | 92x78x93CM |
Applicable materials for reference:
Model | Size | Remark |
capsule | 5#-00# | |
Soft capsule | Size reference capsule | |
Wafer | 6-18MM,thickness above 4MM | |
Oval long tablet | Size reference capsule,thickness 4MM or more | |
Pill | 6-18MM | |
Special-shaped piece | Smooth and rounded edges, such as triangles that can be counted | Size reference tablet |
Candy bears, gummies, the surface is too sticky | ||
Swimming ring type and other intermediate hollows cannot be counted |
Counting Machine YL-2&YL-4 Instruction Manual
Before using this product:
(1) Check whether the glass disc and vibrator are stopped.
(2) Check for any debris on the glass disc and groove of vibrating feeder.
(3) Select the appropriate Orbit, see the accompanying drawings.
(4) Adjustment method of orbit:
1. The inner and outer orbit should be parallel to each other, a width slightly larger than the diameter of the capsules or tablets, its material outlet shall be placed at an intermediate position of electric eye base.
2. Outer orbit should be affixed to the front of the circumference to ensure a smooth sliding of the capsule.
3. Adjust Skew, its height should be slightly larger than the thickness of tablets.
(5) With the size of the bottle and medicine, appropriate chose the material outlet.
(6) Adjust the height of lifting plate and lock Y-Locator.
(7) Turn on the power, set the number, slow start the glass disc and vibrator, check whether tablets slide smoothly and digital display is correct, if both are normal, set number to zero and start the operation.
model | YL-2 |
Speed | 1000-1800pcs/min (1,∅7mm、12mm tablet,2400pcs/min. 2,1#capsule 0.4g/pcs, 1400pcs/min.) |
Loading range | 2~9999 grains/tablet (adjustable) |
Hopper capacity | 10L(1# capsule can hold 10600 capsules) |
Bottle height adjustment range | ≤240MM |
Voltage/Power | 110-220V 50HZ-60HZ/0.1KW |
Net weight/gross weight | 65KG/92KG |
Equipment size | 81x72x84CM |
Package dimensions | 92x78x93CM |
Applicable materials for reference:
Model | Size | Remark |
capsule | 5#-00# | |
Soft capsule | Size reference capsule | |
Wafer | 6-18MM,thickness above 4MM | |
Oval long tablet | Size reference capsule,thickness 4MM or more | |
Pill | 6-18MM | |
Special-shaped piece | Smooth and rounded edges, such as triangles that can be counted | Size reference tablet |
Candy bears, gummies, the surface is too sticky | ||